Assessing the effects of thermal bridging at junctions and around openings
Assessing the effects of thermal bridging at junctions and around openings (IP 1/06) was written by T I Ward and published by BRE in March 2006.
This 6-page paper gives guidance on assessing the effects of thermal bridging at junctions and around openings in the external elements of buildings and how to assess their effect on heat loss or heat gain. It enables estimation of these heat transfers for building regulations compliance calculations. It supports the building regulations for the conservation of fuel and power in all three jurisdictions within the UK. The guidance is primarily intended for junction and opening details that are not as recommended in 'Accredited construction details' or MCRMA/EPIC guidance.
It is a revision of IP17/01 which has been withdrawn.
The contents of the paper are:
- Introduction.
- Building Regulations.
- Numerical modelling.
- Limiting the risk of surface condensation or mould growth.
- Assessing thermal performance.
- References.
[edit] Related articles on Designing Buildings Wiki
- Accredited construction details ACDs.
- BRE articles.
- Building Research Establishment.
- Conventions for calculating linear thermal transmittance and temperature factors.
- Emission rates in the building regulations.
- Reducing thermal bridging at junctions when designing and installing solid wall insulation FB 61.
- Thermal bridge.
- Thermal imaging to improve energy efficiency in building design.
- Thermographic survey.
- U-values.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Changing expectations around competence and compliance
New information sheet from CIAT.
Grenfell investigation files passed to CPS
Angela Rayner apologises on behalf of the British state.
Electrical contractors need to understand the practical implications.
The real barrier to getting more value from digital technology.
Your guide to The Construction Reset at UKCW Birmingham.
Accommodating the Victorian and Edwardian working woman. Book review.
Rethinking passive fire protection in design
PFP demands the same level of design rigour as structure or services.
38% of Gen Zs feel safe when a fire door is wedged open.
Stunning images from around the world
Shortlist for CIOB’s Art of Building photography competition.
Guidance for conversion of traditional pre-1919 stone buildings.
Industrial heritage in the Ruhr
A marked difference to the fate of industrial landscapes in the UK.
Communities will be able to build their own clean energy.